N-HEPTANE 99% - Industrial Solvent
Product Attributes
Category: Industrial Chemicals / Solvents
Formula: C7H16
CAS No.: 142-82-5
Standard: Supplier specification (COA dated 2026-08-01)
Grade: 99% Industrial Grade
Packaging: Drum / ISO tank (subject to order confirmation)
Product Specification Parameters
Batch: YF20260710
Production date: 2026-07-10
Report date: 2026-08-01
Conclusion: All listed results meet the supplier specification.
Production date: 2026-07-10
Report date: 2026-08-01
|
Item |
Unit |
Standard |
COA Result |
Testing Method |
| Density (15°C) | g/cm³ | 0.685–0.693 | 0.689 | ASTM D4052 |
| Appearance | — | Clear & colorless | Clear & colorless | ASTM D4176 |
| Water | ppm | ≤50 | 38 | ASTM D6304 |
| Saybolt color | — | +30 | 30 | ASTM D156 |
| Copper corrosion (100°C, 2 h) | class | ≤1 | 1-a | ASTM D130 |
| Nonvolatile matter | mg/100 mL | ≤1 | 0.31 | ASTM D1353 |
| Refractive index (20°C) | — | 1.3870–1.3890 | 1.3875 | DIN 51423-2 |
| Aromatics | ppm | ≤50 | 0 | GC |
| Benzene | ppm | ≤20 | 0 | GC |
| Sulfur | ppm | ≤1 | N.D. | ASTM D3120 |
| Purity | % (m/m) | ≥99 | 99.37 | GC |
| 3-Methylhexane | % | ≤0.50 | 0.22 | GC |
| 2-Methylhexane | % | ≤0.20 | 0.098 | GC |
| Methylcyclohexane | % | ≤0.30 | 0.11 | GC |
| Distillation IBP | °C | ≥96 | 97.9 | ASTM D86 |
| Distillation DP | °C | ≤105 | 98.3 | ASTM D86 |
| Distillation 5–95% range | °C | 1.5 | 0.1 | ASTM D86 |
Conclusion: All listed results meet the supplier specification.
Application
Extraction and cleaning: Used as a fast-evaporating non-polar solvent in approved extraction, degreasing, and process-cleaning systems.
Adhesives and rubber processing: Suitable for solvent-based adhesive, rubber-cement, and elastomer formulations where n-heptane compatibility has been validated.
Coatings and printing: Can serve as a hydrocarbon solvent or evaporation-rate component in selected coatings, inks, and related formulations.
Chemical and laboratory use: Used as a process solvent, reference material, or intermediate-handling medium subject to the buyer's technical requirements.
Handling and Storage
Highly flammable liquid and vapor. Keep away from heat, sparks, open flames, and static discharge; use grounded, bonded, and explosion-protected equipment.
Store tightly closed in a cool, dry, well-ventilated area away from oxidizing agents. Use only with adequate ventilation and the required personal protective equipment.
Transport, labeling, and use must follow the applicable SDS and local regulations. Final suitability remains the buyer's responsibility.